Design Of Particle Swarm Optimized Two-Degree-Of-Freedom Pid Controllers For Automatic Load Frequency Control Of Two Area Hydro-Hydro Power Plants

dc.contributor.advisorEndalew Ayenew(PhD)
dc.contributor.authorAbraham, Tsige
dc.date.accessioned2025-12-17T11:01:28Z
dc.date.issued2024-05
dc.description.abstractIn Power Systems That Are Interconnected, Any Sudden Small Load Change In Any Of The Powersystems In The Interconnected Grid Causes The Deviation Of Tie-Line Power And Area Frequency.Automatic Load Frequency Control (ALFC) Plays A Very Important Role In Automaticgeneration Control (AGC) To Maintain System Frequency And Active Power Flow At Theirscheduled Values During Any Load Perturbation. In This Thesis, A Two-Degree-Of-Freedomproportional-Integral-Derivative (TDOF-PID) Controller Is Proposed And Successfully Appliedfor ALFC Of Two Interconnected Hydropower Systems. The Objective Is To Control The Frequencydeviation By Maintaining The Real Power Balance Using The TDOF-PID Controller. The TDOF-PID Controller, Integrated With A Particle Swarm Optimization Algorithm, Effectively Addressesthe Issues Of Frequency Deviation And Tie-Line Power Deviation, Which Have A Significant Impacton Power System Stability And Quality. The TDOF-PID Controller Has Demonstrated Exceptionalperformance In Managing The Power Balance And Maintaining System Stability In The Two-Areainterconnected Hydropower System. Compared To An Uncontrolled System, The TDOF-PID-Psocontroller Exhibits Remarkable Improvements Across Various Metrics. It Exhibits Extremely Lowintegral Absolute Error (IAE) And Integral Time Absolute Error (ITAE) Values, Even For Large20% Load Changes In Either Area, Indicating Excellent Load Disturbance Rejection Capabilities.The Frequency Deviations In Both Areas Are Kept To A Minimum, With Changes In The Range Of -0.02 Hz To -2.03 Hz, Even For The 20% Load Changes, Which Is Within The Acceptable Frequencyrange According To Ethiopian Electric Power For Power Quality And System Reliability. Thecontroller Also Demonstrates Effective Management Of The Tie-Line Power Exchange Between Thetwo Areas, With A Maximum Tie-Line Power Deviation Of Only 0.086 Per Unit, Even For Largedisturbances. In Addition To Stability And Reliability, The TDOF-PID-PSO Controller Showspromise In Terms Of Economic Dispatch And Efficiency, As Indicated By The Low IAE And Itaevalues. The Controller's Performance Remains Consistent And Effective Under Both Small (1%)And Large (20%) Load Changes, Demonstrating Its Robustness And Adaptability. It Is Concludedthat The TDOF-PID-PSO Controller Has Proven To Be An Exceptional Solution For Managing Thetie-Line Power Balance And Ensuring The Stability And Reliability Of The Two-Area Interconnectedhydropower System. Its Sophisticated Control Strategies And Adaptability Make It A Highlyrecommended Solution For This Critical Power System Applicationen_US
dc.description.sponsorshipASTUen_US
dc.identifier.urihttp://10.240.1.28:4000/handle/123456789/1874
dc.language.isoen_USen_US
dc.publisherASTUen_US
dc.subjectAgc, Alfc, Interconnected Hydropower, Load Perturbation, Pso, Tdof-Pid.en_US
dc.titleDesign Of Particle Swarm Optimized Two-Degree-Of-Freedom Pid Controllers For Automatic Load Frequency Control Of Two Area Hydro-Hydro Power Plantsen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Abraham Tsige.pdf
Size:
2.19 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description:

Collections